Skip to main content

Advertisement

Table 2 Turbine parameters in nominal operating conditions [22]

From: Heavy duty gas turbine monitoring based on adaptive neuro-fuzzy inference system: speed and exhaust temperature control

Parameter Symbol Unit Value
Compressor pressure ratio PR / 11.3
Fuel mass flow / kg/s 9.1
Lower heating value of fuel LHV kJ/kg 42,532
Exhaust mass flow \( {\dot{m}}_n \) kg/s 539
Exhaust temperature TR °C 510
Nominal frequency F Hz 50-60
Electrical power P Gn MW 157.7
The inside compressor temperature T 2(oc) °C 401.54
Efficiency (simple cycle) η % 34.7
Turbine speed N rpm 3000