Parameter

Value

Radiation shield parameter GSH

0.85

Radiation shield time constant TSH

12.2 s

Exhaust Temperature

537.3 °C

Fuel Demand signal Max Limit (maxK NL )

1.5

Fuel Demand signal Min Limit (minK NL )

-1

K 1 = 25; K 2 = K 3 = 1

\( F1:{T}_R-D\left(1-{\dot{m}}_{fP\cdot U}\right)+0.6\left(1-N\right) \)

\( F2:A+B\cdot {\dot{m}}_{fp\cdot u}+0.5\left(1-N\right) \)

TI = 15.64