Table 4 Total fraction of unburnt gas, maximum temperature, and volume, obtained varying radius, for a fixed length L=0.09m

From: Geometric effects in the design of catalytic converters in car exhaust pipes

Radius (m) Unburnt Gas Temperature (oC) Volume (m3)
0.021 0.6516 1023 0.00021
0.040 0.7883 951.8 0.00063
0.060 0.8502 919.0 0.00135
0.080 0.8842 900.9 0.00234
0.100 0.9056 889.4 0.00362