Skip to main content

Table 3 Total fraction of unburnt gas, temperature, and volume, obtained varying the length for a fixed radius r2=0.06 m

From: Geometric effects in the design of catalytic converters in car exhaust pipes

Length (m)

Unburnt Gas

Temperature (oC)

Volume (m3)

0.05

0.8946

896.7

0.00090

0.06

0.8833

902.5

0.00101

0.07

0.8721

908.1

0.00112

0.08

0.8611

913.6

0.00068

0.09

0.8502

919.0

0.00124