Table 3 Total fraction of unburnt gas, temperature, and volume, obtained varying the length for a fixed radius r2=0.06 m

From: Geometric effects in the design of catalytic converters in car exhaust pipes

Length (m) Unburnt Gas Temperature (oC) Volume (m3)
0.05 0.8946 896.7 0.00090
0.06 0.8833 902.5 0.00101
0.07 0.8721 908.1 0.00112
0.08 0.8611 913.6 0.00068
0.09 0.8502 919.0 0.00124